Coax cable Description

|
The information below is a review of available cable and
recommended service length.
All cables require the appropriate connector to fit its diameter.
Some popular connector types: BNC, F, FME, N, SMA, SMB, TNC, UHF, Mini-UHF etc..
This is only abbreviated information and does not detail specifications on
materials, velocity factors, capacitance, etc.
For simplicity, loss factors (attenuation) are listed only for 900mHz and per
100 FT of length.
Other loss factors for wanted frequency of operation can be calculated by simple
division or multiplication which results close to the actual loss figure needed.
Note: for 1900mHz PCS band, reduce recommended length listed by 40%. Loss factor
is x1.8 approximately.
Notes: Stranded center conductors are more flexible, used for cables where
movement will take place.
But they are harder for field installers to work with attaching connectors.
Solid center conductors make for stiffer cables. Used where cable will not be
subjected to repeated manual
movement of use. PE jackets are stiffer and extra tough for abrasion and
puncture resistance. |
| Universal
Code |
Part
# |
Diameter |
Attenuation at 900mHz for 100Feet |
Recommended
Length (900mHz) |
Construction
Center-cond, Dialectric,
Braid & % of coverage Jacket |
| RG-174 |
RG-174 |
0.110" |
33dB |
< 3 feet |
stranded copper,
poly, bare copper 95%, PVC |
RG-174
Double Shield |
RG-174ULTRA |
0.115" |
22dB |
< 9 feet |
stranded copper,
Foam, Alum.Foil, Tinned Copper 96%, PE, Dk Blue |
| RG-316 |
RG-316 |
0.125" |
29dB |
< 4 feet |
Stranded tined
copper, teflon, tinned braid 96%, PVC (HI-TEMP) |
| RG-58 |
RG-58ST |
0.195" |
16dB |
4 to 20FT |
Soild Copper,
Poly, bare copper 96%, PVC |
| RG-58A/U |
RG-58A/U 'Superflex' |
0.195" |
16dB |
4 to 20FT |
Stranded Copper,
Poly, Bare Copper 96%, PVC |
RG-58A/U
White |
RG-58A/U-W
Marine Spec (White) |
0.195" |
16dB |
4 to 20FT |
Stranded Copper,
Poly, Bare Copper 96%, PVC |
| RG-58 Low Loss |
RG-58 LL |
0.195" |
15dB |
4 to 20FT |
Stranded Copper,
Poly, Bare Copper 96%, PVC |
| RG-58 Dbl Shield |
RG-58ULTRA |
0.195" |
11dB |
22 to 34FT |
Solid Copper,
Foam, Alum.Foil, Tinned Copper 96%, PVC |
| LMR-200 Equivalent |
LMR-200 |
0.195" |
9.9dB |
22 to 34FT |
Solid
Cop,Foam,Alum.Foil,Tinned braid, PE jacket |
| RG-400 |
RG-400 |
0.195" |
14dB |
6 to 25FT |
Solid Cop, Silver
Plated, Teflon, Dual Silver Plated Copper Braid, Clear Tint |
| RG-8X or Mini-8
(Dbl Shield) |
RG-8XULTRA |
0.240" |
7.7dB |
20 to 50FT |
Solid Copper,
Foam, Alum.Foil, Tinned Copper 96%, PVC |
| RG-8X or Mini-8
(Dbl Shield) white |
RG-8XULTRA/W |
0.240" |
7.7dB |
20 to 50FT |
Solid Copper,
Foam, Alum.Foil, Tinned Copper 96%, PVC |
| LMR-240 Times
Micro |
LMR-240 |
0.240" |
7.6dB |
20 to 50FT |
Solid
Cop,Foam,Alum.Foil,Tinned braid, PE jacket |
| RG-214/U Mil-C-17D
(Mil/Aero Spec) |
RG-214 |
0.400" |
8.8dB |
20 to 50FT |
Silver plated
stranded, poly, dual silver plated 95% each, Non Cont PVC |
|
LMR-400 EQUIVALENT
|
RG8=LMR400 |
0.400" |
3.9dB |
40 to 80FT |
Solid Alum-copper
clad, Foam, Alum.Foil,Tinned braid, PE jacket |
| HardLine "Heliax"
or LMR-500up |
|
0.50"-1.50" |
2.2-1.3dB |
70 to 400FT |
Solid or Tube
Copper, Foam or Air, Braid or corrugated copper tube 100%, PVC |
|